house, or for any other reason you need to leave a
zone open. If a component of your security system is
damaged, it can also be bypassed until repairs are
made. Manual bypass arming instructs the control
panel to ignore zones that you designate “open”, so
that the rest of the system can still be armed. (Based
on your instructions, only zones that your installer
has programmed “bypass-enabled” can be bypassed
during manual bypass arming, “auto-bypass
(Away)”
arming or “Stay” arming. Please note that
the fire zone can not be bypassed.)
Press the bypass [
BYP] key, followed by your ACCESS
CODE. You are now in “bypass” mode. The [BYP
] key
will be illuminated and if zones are currently
bypassed they will illuminate as well. Enter the key
numbers corresponding to the zones you wish to
"bypass". Press again on the key if you wish to undo
a zone selection.
If you have entered the correct zone bypass information,
press [
ENTER
]. The [
BYP
] key light will remain “on”
indicating that zones have been bypassed. If you make
an error entering zone numbers, press [
CLEAR
].
By using the “bypass recall” feature, you can
reinstate the latest zone bypass instructions saved in
memory. Press [
BYP] while in “manual bypass
arming” mode and the previous bypass status will be
reestablished. This eliminates the need to enter the
same "bypass" information every time you arm.
Control panel software versions prior to 2.00.
(5) AUTO BYPASS (Away) arming [AWAY] + CODE
Control panel software versions prior to 2.00:
If you want to arm the system without manually entering
zones to be bypassed on the keypad, use “Away” auto-
bypass feature. [
AWAY
] +
ACCESS CODE
s
hould be keyed
in. The control panel will automatically bypass any open
zones after the exit delay terminates and the system will
be armed. The “
READY
” light does not have to be on, but
all open zones must be “bypass-enabled”. If any zones
have been left open, the [
BYP
] light will illuminate to
indicate that zones have automatically been bypassed.
(The fire zone cannot be bypassed.)
FORCE (Away) arming [AWAY]+ CODE
Control panel software versions 2.00 and beyond:
To arm the system rapidly without waiting for the
READY
light, use Force “Away” arming. [
AWAY
] should be pressed,
followed by a valid access code. Once the exit delay
expires, any open zones will not be considered “activated”
by the panel. Open zones will not be protected, and will
not generate an alarm or prevent arming.
These “Away” zones will be activated (and therefore,
protected) as soon as they are closed. Armed status
is indicated by the [
AWAY] key flashing*. (The fire
zone cannot be force armed.)
*
On control panel models 728, 728 EXPRESS and 738
EXPRESS using software version 2.1X, key indicated
will not flash, but will be constantly illuminated. Software
versions 2.2X onward, key indicated does not illuminate.