SEKURE Paradox Spectra 1641 User Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
44 User’s Manual
9.0 APPENDIX A
For Spectra 1689 LED Keypad only
Do not read the following if you have not read
these sections:
User Access Codes (see section 3.4)
System’s Clock (see section 5.4)
Auto-Arm Time (see section 4.9)
After entering the 3-digit section you wish to program, the
[ARM1] and [STAY1] will flash. If a value is programmed, the
number corresponding to the first digit of the programmed
value will also illuminate. At this point, you can begin entering
the required data. After entering a digit, the number
corresponding to the following programmed digit will
illuminate and so forth. For example, if you wish to change
User Code 004 from 123456 to 454545, after entering section
[004], number [1] will turn on. Press the [4] button and
number [2] will turn on, then press the [5] button and number
[3] will turn on...
OR
After entering the desired 3-digit section and before entering
any data, press the [ENTER] button to access the Data Display
Mode. The [ARM1] and [STAY1] Lights will illuminate. Once in
the Data Display Mode, pressing the [ENTER] button will scroll
through the digits of the current section and the [BYP], [MEM] &
[TRBL] Lights will flash. When viewing the last digit in the
section, pressing the [ENTER] button will automatically
advance to the next section. Press [CLEAR] to exit.