11 User Guide
Stay Arming
This method allows you to roam freely within the premises while the perimeter is fully armed. Stay zones are
zones that are bypassed when Stay arming. For example, if you plan on staying in for the night, doors and
windows can be armed without arming other zones like motion detectors. Stay arming can also be activated
using Auto-Arming (see Auto-Arming on page 12) or One-Touch Arming (see One-Touch Arming on page 12).
Bypassing a Zone
Bypassing a zone allows you to ignore (deactivate) specified zones the next time the system is armed. For
example, you may wish to bypass certain zones when workers are renovating part of your home. Once the
system is disarmed, the bypass entries are erased. When zones are bypassed, the [
BYP] key will illuminate.
Zone bypassing can also be activated by using One-Touch Bypass Programming (see page 12). If One-Touch
Bypass Programming is enabled, press the [
BYP] key for three seconds to enter bypass programming. To
remove the Bypass feature from a zone, in step 3 enter the zone number again or press [
CLEAR] to erase all
current entries. Press [
CLEAR] + [ENTER] to delete bypassed zones.
Bypass Recall Feature
After disarming the system, bypass entries are erased. The Bypass Recall feature reinstates the previous
bypass entries saved in memory. This eliminates the need to manually re-program the bypass entries every
time you arm your system.
How do I Stay arm?
1 Close all zones in the desired partition (except Stay zones).
2 Press the [
STAY] key.
3 Enter your [
USER CODE].
4 If you have access to both partitions (see Partitioning on page 19): press the key corresponding to the
desired partition, [1] or [2]. For both partitions, press the other key after the confirmation beep.
How do I bypass zones?
1 Press the [
BYP] key.
2 Enter [
USER CODE]. The [BYP] key will flash. Press [ENTER] to bypass all open zones or go to step 3.
3 Illuminate the number(s) corresponding to the zone(s) you want to bypass by entering the zone number.
Solid on = Zone open, Flash = Zone bypass, Off = Zone closed, not bypassed.
4 Press the [
ENTER] key to save and exit. Press [CLEAR] twice to exit without saving.
How do I recall bypass entries?
1 Press the [
BYP] key.
2 Enter your [
USER CODE].
3 Press the [
BYP] key.
4 Press the [
ENTER] key.