BREAK-OUT BOX 229
SNAPSHOT SAVE
After completion of the data capture, a <SNAPSHOT SAVE> display allows you to save
the data for later review.
Press y to save this data set or n to continue without saving the data. The current
snapshot can be reviewed immediately even if not saved.
ACTIVE KEYS
y Save snapshot data.
n Continue to Data Display phase without saving snapshot data.
DATA DISPLAY PHASE
At the completion of the data capture phase, <Sample> and a time stamp are displayed at
the bottom of the screen. Data captured in the snapshot mode can be displayed in all of the
formats that are available in the <DATA LIST> mode, except <STRIP CHART>.
ACTIVE KEYS
l r Sequence through the sample displayed.
u d Move the display up or down one parameter.
au Move the display one page. (<DATA LIST> mode only.)
ad
y Change the highlighted parameter to the next parameter in the list. (<LED/
LIST>, <BAR GRAPH> and <LINE GRAPH> modes only.)
n Change the highlighted parameter to the previous parameter in the list.
(<LED/LIST>, <BAR GRAPH> and <LINE GRAPH> modes only.)
AY Change to the next parameter not currently displayed.
(<LED/LIST>, <BAR GRAPH> and <LINE GRAPH> modes only.)
AN Change to the previous parameter not currently displayed.
(<LED/LIST>, <BAR GRAPH> and <LINE GRAPH> modes only.)
! Go to <DATA LIST> mode.
@ Go to <LED/LIST> mode.
# Go to <BAR GRAPH> mode.
$ Go to <LINE GRAPH> mode.
& Toggle between raw and converted data for voltage.
( Change between large and compressed character size.
) Turn cursor on and off.
ah Display parameter information.
s Print data list.
HINT
The snapshot is stored in the Program Card. Make sure that you
have the same Program Card when viewing stored data.