16 REFERENCE & INSTALLATION MANUAL
5 KEYSWITCH PROGRAMMING
The DigiplexNE control panel can support up to 32 keyswitch zones in addition to the 96 standard zones. A keyswitch allows a user to arm or disarm a
system by pressing a key or by toggling a keyswitch. A keyswitch can also be used to generate a Utility Key event which can then be used to activate or
deactivate PGM outputs connected to the DigiplexNE system. The keyswitches are connected to the hardwired input terminals of either the control panel,
zone expansion modules or the keypad. For installation instructions, see section 2.9 on page 4. Keyswitches must be programmed as described in this
section (see Figure 5-1). UL Note: Keyswitches are not to be used in UL Listed systems.
Figure 5-1: Keyswitch Programming
5.1 KEYSWITCH NUMBERING
S
ECTIONS [0501] TO [0532]
Keyswitch Numbering allows you to assign any hardwired input in the
system to any of the 32 keyswitch zones in the control panel. It identifies
where the keyswitch is connected and which keyswitch zone is assigned to
the keyswitch (see Figure 5-2).
Figure 5-2: Example of Keyswitch Numbering
5.2 KEYSWITCH DEFINITIONS
Keyswitch Definitions determine how the control panel reacts when a
keyswitch is activated.
5.2.1 Keyswitch Disabled
SECTIONS [0601] TO [0632]: FIRST DIGIT = 0
Disables keyswitch input.
5.2.2 Momentary Keyswitch
SECTIONS [0601] TO [0632]: FIRST DIGIT = 1
To arm a partition using the Momentary Keyswitch, turn on the keyswitch for
approximately three seconds then turn it off. Repeating this sequence will
disarm the system. The selected Keyswitch Option (see section 5.4)
determines the type of arming.
5.2.3 Maintained Keyswitch
SECTIONS [0601] TO [0632]: FIRST DIGIT = 2
To arm a partition using the Maintained Keyswitch, turn the switch from the
ON to the OFF position. To disarm a partition set the keyswitch in the ON
position. The selected Keyswitch Option (see section 5.4) determines the
type of arming. If the keyswitch’s Arm Only option is enabled, the control
panel will not perform any action when the switch is in the on position.
Press & hold the
[0] key
Enter your
[
INSTALLER CODE]
Enter 4-digit
[
SECTION]
Keyswitch Numbering
Sections [0501] to [0532] represent
keyswitches 1 to 32 respectively
Keyswitch Parameters
Sections [0601] to [0632] represent
keyswitches 1 to 32 respectively
Enter the module’s 8-digit
[
SERIAL NUMBER] where the
keyswitch is installed
Enter the 3-digit [
INPUT
NUMBER] where the
keyswitch is connected
Keyswitch Definition
First Digit
Keyswitch Partition
Assignment
Second Digit
Keyswitch Options
Feature Select
Press [
ENTER]
Keyswitch Definitions
[0] Disabled (default)
[1] Momentary Keyswitch
[2] Maintained Keyswitch
[3] Generates a Utility Key Event on Open
[4] Generates a Utility Key Event on Open & Close
Keyswitch Partition Assignment
[0] Not assigned to partition(s) (default)
[1] Assigned to partition 1
[2] Assigned to partition 2
[3] Assigned to partition 3
[4] Assigned to partition 4
[5] Assigned to partition 5
[6] Assigned to partition 6
[7] Assigned to partition 7
[8] Assigned to partition 8
Keyswitch Options
Default = All OFF
[1] to [3] = Future Use
[4] Stay/Instant Disarm
[5] Arm Only
[6] Stay Arming*
[7] Force Arming*
[8] Instant Arming*
* Select one only; if all are OFF, defaults to regular
arming.
Select one
only
Select one
only
Set
options
Control Panel
SN#: 020000A2
Keyswitch B
Keyswitch C
Keyswitch
Zone # Section Serial# Input#
Keyswitch A: 1 = [0501] 020000A2 001
Keyswitch B: 2 = [0502] 34000041 002
Keyswitch C: 3 = [0503] 34000041 006
Input 2
Input 6
Keyswitch A
Input 1
Input Terminals
1 2 3 4 5 6 7 8
C
OMMUNICATION
N
ETWORK
Zone Expansion Module
SN#: 34000041
Input Terminals
1 2 3 4 5 6 7 8
Combus