DIGIPLEXNE CONTROL PANEL 33
Delay, Bell Squawk, One-touch Arming, Panic Alarms and many more. All
zones, keyswitch zones, user codes and system modules are assigned to
specific partitions, making this a true partitioned system. Enable the
option(s) that correspond to the desired partition(s):
11.9.1 Panel Partition Assignment
SECTION [3020]
(Default = 00) The control panel will report system events as originating
from one or all enabled partitions. The System Troubles (i.e. AC Failure,
TLM Failure, etc.) can only be viewed through the partitions enabled in this
section. Enter a 2-digit decimal number from 01 to 08 which represent
partitions 1 to 8. Enter 00 to disable this feature.
11.10 SHABBAT FEATURE
S
ECTION [3030]: OPTION [4]
(Default = disabled) When option
[4]
is enabled, detectors and keypads in the
system no longer display system status through the LCD and/or LEDs between
noon (12:00PM) Friday and midnight (12:00AM) Saturday. Normal operation is
re-instated Sunday morning at 12:00:01AM. If required, a user can access all
the usual commands and features during the Shabbat period by pressing a key
or by entering their access code (also depending if and how Confidential Mode
is enabled in the keypad). When no actions have occurred for two minutes, the
Shabbat Feature will re-activate. During the Shabbat period:
the LCD keypads only display the date and time
the backlight is disabled
the LED indicators on modules are disabled
11.11 INSTALLER FUNCTION KEYS
Press and hold the [0] key and key in the [INSTALLER CODE] to access the
installer functions and then...
For LCD keypads: Press the key indicated in the list below that
corresponds to the function you wish to activate.
For Grafica keypads: Press the center action key (Options), highlight the
desired function and then press the left action key (Select).
11.12 MODULE RESET
S
ECTION [4001]
To reset a module connected to the combus to its default values, key in the
module's serial number into section [4001].
11.13 LOCATE MODULE
S
ECTION [4002]
To locate a specific module on the combus, key in the module's serial
number into section [4002]. The green
LOCATE LED on the module flashes
until the serial number is re-entered into the section or the module’s tamper
or unlocate switch is pressed.
11.14 MODULE PROGRAMMING
S
ECTION [4003]
All modules connected to the combus are programmed through the control
panel. To program a module, enter section [4003] to enter Module
Programming Mode (see section 3.5), key in the module's serial number
and follow the programming indicated in the DigiplexNE Modules
Programming Guide. To exit this mode, press the [
CLEAR] key until Normal
Mode is displayed.
11.15 MODULE AND LABEL BROADCAST
S
ECTION [4004]
Module Broadcast
To copy the contents of the programming sections from one module to one
or more of the same type, key in the serial number of the source module in
section [4004], enter the serial numbers of all the destination modules and
press [
ACC] if using an LCD keypad or the center action key (Start) if using
a Grafica keypad.
Label Broadcast
Copy the User Labels, Zone Labels (sections [0301] to [0396]), the Door
Labels (sections [2301] to [2332]) and the Partition Labels (sections
[3100], [3200], [3300], [3400], [3500], [3600], [3700] and [3800]) to all the
modules in the system that support these labels. To transmit the labels, in
section [4004], enter the control panel’s serial number. From the
Destination screen, do not enter a serial number and press [
ACC] if using an
LCD keypad or the center action key (Start) if using a Grafica keypad.
The Module and Label Broadcast feature will only work when a
module is broadcasting its data to a module or to modules of
the same type and
model number. For example, an APR-PRT1
(Printer Module) cannot broadcast to an APR3
-PRT1. Likewise,
a DGP
module cannot broadcast to a DGP2 module.
Module Broadcast Example:
Using an LCD keypad, to program two zone expansion modules
(SN#34540075 and SN#34412100) with the same settings and options of
zone expansion module SN#34540033:
1) Press and hold the [0] key.
2) Enter your [
INSTALLER CODE] and then enter section [4004].
3) Enter 34540033, 34540075, and 34412100 and then press [
ACC].
The control panel automatically copies the contents of 34540033 into the
other two zone expansion modules.
Label Broadcast Example:
Using a Grafica keypad, to copy the labels of the control panel
(SN#020000A2) to all modules that support the labels:
1) Press and hold the [0] key.
2) Enter your [
INSTALLER CODE] and then enter section [4004].
3) Enter 020000A2.
4) From the Destination screen, press the center action key (Start).
The control panel will automatically copy its labels to all supporting modules.
11.16 SYSTEM DATE & TIME
The System Date and Time is programmed through the User Menu, please
refer to Clock Loss in section 15.12.
Option Description Option Description
[1] Partition 1 [5] Partition 5
[2] Partition 2 [6] Partition 6
[3] Partition 3 [7] Partition 7
[4] Partition 4 [8] Partition 8
Keys Description
[STAY]
TEST REPORT: Sends the Test Report report code programmed
in section [3902] to the Monitoring Station.
[FORCE]
CALL WINLOAD: Dials the PC telephone number programmed
in section [3010] to communicate with a computer using
WinLoad.
[ARM]
ANSWER WINLOAD: Forces the control panel to answer a call
made by the Central Monitoring Station that is using WinLoad.
[DISARM]
CANCEL COMMUNICATION: Cancels all communication with
the Monitoring Station or WinLoad until the next reportable event.
[MEM]
INSTALLER TEST MODE: Perform walk tests where the bell or
siren squawks once when a zone opens and twice when it
closes. Press [
MEM] again to exit. Partitions cannot be armed if
the Installer Test Mode is enabled.
[TRBL]
START MODULE SCAN: Verifies the status of modules on the
combus. The LCD Keypads display the serial number of each
module connected to the combus.
[ACC]
START VOLTMETER READING (DGP2-641 only): Verifies if the
combus is supplying sufficient power at the keypad’s location
(refer to the LCD Keypad Reference & Installation Manual).