8.1 REPORTING ENABLED
S
ECTION [3036]: OPTION [3]
(Default = disabled) With option [3] ON in section [3036], Event Reporting is
enabled. When an event (e.g. zone in alarm) occurs in the system, the
control panel verifies if a report code was programmed in the section
corresponding to the event. If a report code is programmed, the control panel
dials the Monitoring Station telephone number defined by the Event Call
Direction feature. When the Monitoring Station answers, the control panel
transmits the system account code, followed by the programmed report code.
8.2 REPORT CODES
A report code is a 2-digit or 1-digit hexadecimal value, consisting of digits from
0 to F. For a comprehensive list of the events and their relevant sections,
please refer to the DigiplexNE Programming Guide. Only the Ademco Slow,
Silent Knight, Sescoa and Pager Formats support 1-digit report codes.
When a specific event occurs, the control panel will send the programmed
report code to the Monitoring Station. The method of report code
transmission is defined by the following two items: Reporting Formats
(see section 8.7) and Event Call Direction (see section 8.8). These two
items define how and where the report codes are transmitted. If you are
using the Ademco CID or SIA formats, an Auto Report Code Programming
feature is available (see section 8.15). The following sub-sections provide a
brief description of the events that the control panel can report:
8.2.1 Zone Alarm and Alarm Restore Report Codes
SECTIONS [0201] TO [0296]: FIRST AND SECOND BRACKETS
A report code can be programmed for each of the 96 available zones. Each
section from [0201] to [0296] corresponds to a zone from 01 to 96. The first
set of 2 digits in the sections refer to the Alarm Report Codes that can be
sent to the Monitoring Station to identify which zones generated an alarm.
The second set of 2 digits in the sections refer to the Alarm Restore Report
Codes that can be sent to the Monitoring Station when a zone closes or
once the bell has cut-off after generating an alarm (see section 7.2). Also,
refer to Zone Restore Report Options in section 8.14.
8.2.2 Tamper and Tamper Restore Report Codes
SECTIONS [0201] TO [0296]: THIRD AND FOURTH BRACKETS
A report code can be programmed for each of the 96 available zones. Each
section from [0201] to [0296] corresponds to a zone from 01 to 96. The
third set of 2 digits refer to the Tamper Report Codes that can be sent to the
Monitoring Station to identify which zone experienced a tamper or wire
fault. If the Tamper Recognition Options (see section 7.5) are disabled, the
control panel will not report the occurrence of any tampers or wire faults.
The fourth set of 2 digits refer to the Tamper Restore Report Codes that can
be sent to the Monitoring Station to identify which zone was restored.
8.2.3 Keyswitch Arming
SECTIONS [0701] TO [0732]
A report code can be programmed for each of the 32 keyswitch zones.
Each section from [0701] to [0732] corresponds to a keyswitch from 1 to
32. When using a keyswitch to arm a partition, the control panel can send
the report code to the Monitoring Station identifying which keyswitch was
used. The control panel will not send report codes for keyswitches that are
defined with the PGM Activation definition.
8.2.4 Keyswitch Disarming
SECTIONS [0801] TO [0832]
A report code can be programmed for each of the 32 keyswitch zones. Each
section from [0801] to [0832] corresponds to a keyswitch from 1 to 32. When
a keyswitch is used to disarm a partition, the control panel can send the
report code to the Monitoring Station identifying which keyswitch was used.
The control panel can transmit the report codes every time a partition is
disarmed or only when it is disarmed following an alarm. Also, refer to Disarm
Reporting Options in section 8.13. The control panel will not send report
codes for keyswitches that are defined with the PGM Activation definition.
8.2.5 Access Codes Arming
SECTIONS [2001] TO [2099]
A report code can be programmed individually for each User Access Code
from 01 to 98 in sections [2001] to [2098]. User Access Codes from 99 to
999 use a common report code in section [2099]. When an access code is
used to arm a partition, the control panel can send the report code to the
Monitoring Station identifying which access code was used.
8.2.6 Access Codes Disarming
SECTIONS [2101] TO [2199]
A report code can be programmed individually for each User Access Code
from 01 to 98 in sections [2101] to [2198]. User Access Codes from 99 to
999 use a common report code programmed in section [2199]. When an
access code is used to disarm a partition, the control panel can send the
report code to the Monitoring Station identifying which access code was
used. The report code can be transmitted when a partition is disarmed or
only when disarmed following an alarm. Also, see section 8.13.
8.2.7 Special System Reporting Codes
When the system generates one of the following events, the control panel
can send the report code to the Monitoring Station identifying the event:
8.2.8 Special Arming Report Codes
When the partition arms using a special arming feature, the control panel
can send the report code identifying how the system was armed.
Section Event Description
[3900] Cold Start
control panel re-starts after complete
shutdown (total power loss)
[3901] Warm Start
control panel resets due to sudden
problem other than power loss
[3902] Test Report
report generated automatically
(see section 8.12)
[3903] to [3904] Future Use
[3905] WinLoad Log Off
control panel ends communication with
WinLoad
[3906] Installer In installer enters programming mode
[3907] Installer Out installer exits programming mode
[3908] to [3909] Future Use
Section Event Description
[3910] Auto-Arming when Auto-Arming (see section 6.9)
[3911] PC Arming
system armed using WinLoad or NEware
software
[3912] Late to Close when Auto-Arming (see section 6.9)
[3913] No Movement
when No Movement Auto-Arming
(see section 6.10)
[3914] Partial Arming
when partitions are Stay, Instant or Force
Armed or armed with bypassed zones
[3915] Quick Arming
partitions armed with a One-Touch Arming
feature (see section 6.15)
[3916] Early to Close
partition armed before Arming Report
Schedule (see section 8.3.2)
[3917] Late to Close
partition armed after Arming Report
Schedule (see section 8.3.2)
[3918] Remote Arm
partition armed with the InTouch Voice-
Assisted Arm/Disarm Module (APR3-
ADM2)
[3919]
Closing Delinquency
Partition hasn’t been armed before the
programmed Closing Delinquency Timer
elapsed (see section 8.16).