DIGIPLEXNE CONTROL PANEL 25
8.2.9 Special Disarming Report Codes
When using one of the special disarming features listed below, the control
panel can send the report code to the Monitoring Station identifying how the
system was disarmed. The control panel can transmit the report codes
every time a partition is disarmed or only when it is disarmed following an
alarm. Also, refer to Disarm Reporting Options in section 8.13.
8.2.10 Special Alarm Report Codes
When an alarm is generated, the control panel can send the report code to
the Monitoring Station identifying the type of alarm.
8.2.11 System Trouble Codes
When a trouble is detected, the control panel can send the report code to
the Monitoring Station identifying the type of trouble.
8.2.12 System Trouble Restore Codes
When a trouble described in sections [3940] to [3961] is corrected, the
control panel can send the report code to the Monitoring Station
.
If the Telephone Line Monitoring (see section 9.1) is disabled,
the control panel will not transmit the TLM report code.
8.3 REPORT ARMING AND DISARMING
The following two features combine to identify when a partition should be
armed and disarmed and enable the control panel to communicate
deviations from the normal schedule to the Monitoring Station.
8.3.1 Enable Arming and Disarming Report Schedules
(Default = disabled) If the partition is armed or disarmed during times not
programmed in the Arming and Disarming Report Schedules (see section
8.3.2), the control panel will send the corresponding report code Early to
Section Event Description
[3920] Cancel Auto-Arm
partition disarms during the Auto-Arm’s
60-sec. delay (see section 6.9)
[3921] Quick Disarm
partition disarms using One-Touch
Disarming feature (see section 6.15)
[3922] PC Disarm
system disarmed using WinLoad or
NEware software
[3923]
PC Disarm after
Alarm
system disarmed using WinLoad or
NEware software after an alarm occurs
[3924] Cancel Alarm
indicates that an alarm was cancelled
even though the system was not armed
when the alarm occurred.
[3925] Future Use Future Use
[3926] Early to Open
partition disarmed before Disarming
Schedule (see section 8.3.2)
[3927] Late to Open
partition disarmed after Disarming
Schedule (see section 8.3.2)
[3928] Remote Disarm
partition disarmed with InTouch Voice-
Assisted Arm/Disarm Module (APR3-
ADM2)
Section Event Description
[3930] Emergency Panic
(non-medical)
the panic keys [1] and [3] were pressed
(see section 7.6)
[3931] Auxiliary Panic
the panic keys [4] and [6] were pressed
(see section 7.6)
[3932] Fire Panic
the panic keys [7] and [9] were pressed
(see section 7.6)
[3933] Recent Closing
an alarm is generated within the Recent
Close Delay (see section 8.10)
[3934] Police Code
Confirmation of an alarm condition
occurred during the Police Code Timer’s
delay (see section 7.4).
[3935]
Auto Zone
Shutdown
the control panel stops regenerating
alarms on a zone during the same armed
period (see section 4.5.1)
[3936] Duress
a Duress enabled access code is keyed in
(refer to the Digiplex/DigiplexNE LCD
Keypad Reference & Installation Manual)
[3937] Keypad Lockout
too many invalid codes entered
(see section 6.17)
Section Event Description
[3940] TLM1 Failure TLM failure on main telephone line
[3941] AC Failure
AC power not detected. Also, see Power
Fail Report Delay in section 8.11
[3942] Battery Failure
battery is disconnected or the battery
voltage is less than or equal to 10.5V
[3943] Auxiliary Supply
the aux power supply’s current is greater
than or equal to 1.1A
[3944]
Bell Output
bell output is disconnected or the current
is greater than or equal to 3A
[3945] Clock Loss panel time lost (see section 11.16)
[3946] Fire Loop Trouble tamper on a fire zone (see section 4.3)
[3947] TO [3949] Future Use
[3950] Bus Fault a module was removed from the combus
[3951] Module Tamper
tamper/wire fault on module (not a motion
detector) on the combus
[3952] ROM Check Error on-board Read-Only Memory trouble
[3953] Module TLM
TLM failure detected on Voice-Assisted
Arm/Disarm Module (APR3-ADM2)
[3954]
Module Fail to
Communicate
DGP2-DVAC failed to communicate with
the Monitoring Station
[3955] Printer Fault Printer Module detected an error
[3956] Module AC Failure no AC power detected on a module
[3957]
Module Battery
Failure
battery on a module is disconnected or the
battery voltage is low
[3958]
Module Auxiliary
Failure
The AUX output on a module has
exceeded current limits
[3959] Future Use Future Use
[3960]
Wireless Trans-
mitter Low Battery
the battery voltage is low on a wireless
transmitter
[3961]
Wireless Module
Supervision Failure
This report code is global unless using the
Contact ID or SIA reporting formats
[3962] to [3964] Future Use
[3965] Fail to Com 1 Phone Number 1 failed to communicate*
[3966] Fail to Com 2 Phone Number 2 failed to communicate*
[3967] Fail to Com 3 Phone Number 3 failed to communicate*
[3968] Fail to Com 4 Phone Number 4 failed to communicate*
* No “Fail to Communicate” for Pager telephone numbers
Section Event Section Event
[3970] TLM1 Restored [3981] Module Tamper Restored
[3971] AC Restored [3982] ROM Check Error Restored
[3972] Battery Restored [3983] Module TLM Restored
[3973]
Auxiliary Supply
Restored
[3984]
Module Fail to Communicate
Restored
[3974] Bell Output Restored [3985] Printer Fault Restored
[3975] Clock Loss Restored [3986] Module AC Failure Restored
[3976] Fire Loop Restored [3987] Module Battery Restored
[3977] Future Use [3988] Module Auxiliary Restored
[3978] Future Use [3989] Future Use
[3979] Future Use [3990]
Wireless Transmitter Battery
Restored
[3980] Bus Fault Restored [3991]
Wireless Module Supervision
Restored